For the management of DALI BUS there is not an exact cable type recommended, but it is
important to keep some installation conditions. For DALI BUS lines up to 100 m the recommended
min. conductor cross section is 0.5 mm2. For management between 100 m - 150 m a cross section
of 0.75 mm2 and more than 150 m the recommended min is 1.5 mm2. Management of more than
300 m is not recommended. The voltage drop at the end of the installation may not be greater
than 2 V.
Power supply | ||||
---|---|---|---|---|
AC power supply | ||||
Voltage: | 100- 230 VAC | |||
Frequency: | 47-63 Hz | |||
Maximum power consumption: | 2 W | |||
Power consumption when idle: | < 0.4 W | |||
Maximum lamp power: | 400W | |||
Communication Interface | ||||
Bus: | DALI | |||
Transparent DALI: | Yes | |||
Functions: | ON/OFF/DIM | |||
Over the air firmware update: | Yes, over LoRa | |||
Operating mode: | Message from the server | |||
Fallback when communication fails: | Last known commands series | |||
LPWAN communication | ||||
LoRaWAN | ||||
LoRaWAN specification: | 1.0.1 | |||
Registration method: | ABP | |||
Class: | C | |||
Frequency: | 868 MHz (ISM) | |||
TX Power: | 12,7dBm | |||
Antenna: | Internal | |||
General information | ||||
IP coverage: | IP65 | |||
Dimensions: | Ø 88 x 62 mm | |||
Operational temperature: | -30 .. +50 °C | |||
Weight: | 160 g | |||
Mounting: | NEMA plug | |||
Mounting standard | Standard ANSI C136.41 Dimming Receptacle | |||
Precision Real Time Clock (RTC) | Yes, from GPS | |||
Automatic positioning | Yes, from GPS | |||
Ordering code | ||||
Code | Description | |||
ACR-SLC-DALI-NEMA | NEMA smart street light module |